T4x-SERIES QUICKSTART GUIDE
14
EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER
Camera
EXTERNAL TRIGGER
Vext 30 Vdc max.
A
B
V
CC
~
~
+
-
V
Signal
I1A
I1B
I
in
Figure 8 - PNP External Trigger Using External Power
Camera
EXTERNAL TRIGGER
Vext 30 Vdc max.
A
B
Signal
V
V
CC
~
~
+
-
I1A
I1B
Figure 9 - NPN External Trigger Using External Power
INPUT 2 CONNECTIONS
INPUT 2 CONNECTIONS USING CBX POWER
CAUTION
Power is available directly to the Input Device, independently from the
Power Supply Switch inside the CBX.
Figure 10 - PNP Input 2 Using CBX Power Figure 11 - NPN Input 2 Using CBX Power
CBX500
Function
+V
Power Source - Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference - Inputs
Vedere la pagina 13